In the intricate ecosystem of data centers, where every component plays a critical role in maintaining seamless operations, coaxial cable assemblies stand as unsung heroes. These specialized cables facilitate the transfer of high-frequency signals with minimal loss, making them indispensable for applications ranging from server interconnects and antenna systems to testing equipment and network infrastructure. However, not all coaxial cable assemblies are created equal—choosing the right one requires a nuanced understanding of data center requirements, technical specifications, and environmental factors. This guide breaks down the key considerations to help you select coaxial cable assemblies that optimize performance, reliability, and cost-effectiveness in your data center.

Understand Data Center-Specific Requirements

Data centers operate under unique conditions that set them apart from other environments, and these conditions directly influence the type of coaxial cable assemblies needed. Unlike residential or small-office setups, data centers handle massive volumes of data at ultra-high speeds, often 24/7, with zero tolerance for downtime. They also house dense arrays of equipment, generating significant heat and electromagnetic interference (EMI)—factors that can degrade signal quality if cables are not properly designed.

First, identify the primary function of the coaxial cable assembly in your data center. Will it be used for connecting servers to switches, linking antennas to transceivers, or supporting high-speed data transmission between racks? Each application has distinct demands: for example, antenna connections may require cables with superior shielding to resist EMI, while inter-rack connections might prioritize low signal loss over long distances.

Next, consider bandwidth needs. Modern data centers handle 5G, cloud computing, and IoT traffic, all of which demand cables capable of transmitting signals at high frequencies (often up to 67 GHz or higher). Coaxial cables with higher frequency ratings ensure they can support current and future data rates, preventing the need for premature replacements as your infrastructure scales.

Evaluate Key Technical Specifications

Technical performance is the cornerstone of any coaxial cable assembly, and several specifications deserve close scrutiny:

Frequency Range

The frequency range of a coaxial cable determines the maximum signal speed it can support. For data centers, this is non-negotiable—cables must match or exceed the frequency requirements of your equipment. For example, 5G infrastructure and high-speed Ethernet often require cables rated for 18 GHz or higher, while legacy systems may function with lower ranges (e.g., 6 GHz). Choosing a cable with a frequency range that aligns with your current needs while leaving room for future upgrades (e.g., 28 GHz or 67 GHz) is a strategic investment.

Attenuation

Attenuation refers to the loss of signal strength as it travels through the cable. In data centers, where cables may run long distances between racks or floors, minimizing attenuation is critical to maintaining signal integrity. Attenuation increases with frequency and cable length, so look for cables with low attenuation ratings (measured in dB per 100 feet) at your target frequency. For instance, a cable with 0.5 dB attenuation at 10 GHz will outperform one with 1.2 dB attenuation at the same frequency when transmitting over 50 feet.

Impedance Matching

Impedance (measured in ohms) is the resistance a cable offers to signal flow. Mismatched impedance between the cable, connectors, and connected equipment causes signal reflection, leading to loss, distortion, or even equipment damage. Data center equipment typically uses 50-ohm coaxial cables, as this impedance balances power handling and signal efficiency—ideal for high-frequency, high-power applications like RF transceivers. Avoid mixing 50-ohm cables with 75-ohm equipment (common in video systems) unless adapters are used, as this will degrade performance.

Shielding

Data centers are dense with electronics, creating a noisy environment filled with EMI from servers, power supplies, and other cables. Coaxial cables rely on shielding to block EMI and prevent signal leakage, which can interfere with nearby equipment. The most effective shielding options for data centers include:

  • Braided shielding: Consists of woven metal strands (usually copper or aluminum) that provide flexibility and moderate EMI protection.
  • Foil shielding: A thin metal layer (often aluminum) wrapped around the inner conductor, offering 100% coverage and superior protection against high-frequency EMI.
  • Dual shielding: Combines braided and foil shielding for maximum protection—essential in high-interference areas of the data center.

Choose shielding based on your environment: dual shielding is ideal for racks near power distribution units (PDUs) or high-power transmitters, while braided shielding may suffice in less congested zones.

Consider Physical and Environmental Factors

Beyond technical performance, the physical characteristics of coaxial cable assemblies must align with data center logistics and conditions:

Durability and Flexibility

Data center cables are often routed through tight spaces, bent around corners, or moved during equipment upgrades. A cable that is too rigid may crack under repeated bending, while one that is overly flexible might kink, disrupting signal flow. Look for cables with robust outer jackets (e.g., PVC, TPE, or LSZH) that resist abrasion, oil, and chemicals. For areas with frequent movement, choose assemblies with stranded inner conductors, which offer greater flexibility than solid conductors.

Temperature Resistance

Data centers generate significant heat, with ambient temperatures often reaching 80°F (27°C) or higher. Coaxial cables must withstand these conditions without degrading. Cables rated for wide temperature ranges (-40°C to 85°C or higher) are ideal, as they remain stable in both hot operating environments and cooler backup areas (e.g., server rooms with climate control). Avoid cables with jackets that soften or crack at high temperatures, as this can expose internal components to damage.

Connector Quality

The connectors at the ends of a coaxial cable assembly are as critical as the cable itself—poorly designed connectors can negate even the best cable’s performance. Look for connectors made from high-conductivity materials (e.g., gold- or silver-plated brass) to ensure low resistance and corrosion resistance. Common data center connectors include:

  • SMA: Compact and widely used for high-frequency applications (up to 18 GHz), ideal for small-scale connections.
  • N-type: Rugged and durable, supporting frequencies up to 11 GHz, suitable for outdoor or high-power indoor use.
  • 7/16 DIN: Designed for high-power, high-frequency applications (up to 7.5 GHz), often used in cellular base stations within data centers.

Ensure connectors are properly crimped or soldered to the cable—loose connections cause signal loss and can lead to overheating.

Assess Customization and Compatibility

Data centers rarely have one-size-fits-all setups, so off-the-shelf coaxial cable assemblies may not always meet your needs. Consider whether customization is necessary:

  • Length: Standard lengths (e.g., 3ft, 6ft, 10ft) may work for some applications, but longer runs (50ft+) or ultra-short jumps between adjacent racks may require custom-cut cables to avoid excess slack (which can cause tangling) or signal loss from overly long lengths.
  • Connector combinations: You may need assemblies with different connectors on each end (e.g., SMA to N-type) to bridge incompatible equipment.
  • Jacket color: Color-coding cables by function (e.g., red for power, blue for data) simplifies maintenance and reduces human error during upgrades.

Additionally, verify compatibility with existing infrastructure. For example, if your data center uses 10GBASE-T Ethernet switches, ensure the coaxial cables support the required frequency and impedance to avoid bottlenecks.

Prioritize Quality and Compliance

In data centers, where downtime can cost thousands of dollars per minute, the reliability of coaxial cable assemblies is non-negotiable. Choose assemblies from manufacturers that adhere to industry standards, such as:

  • ISO 9001: Ensures consistent quality management systems.
  • RoHS: Guarantees compliance with environmental regulations, avoiding hazardous materials.
  • MIL-STD: Military-grade standards for durability, ideal for mission-critical data center applications.

Reputable manufacturers also provide test reports (e.g., attenuation, VSWR, and shielding effectiveness) to validate performance claims. Avoid low-cost, uncertified cables—they may save money upfront but often fail prematurely, leading to costly outages.

Why FRS Factory Stands Out for Data Center Coaxial Cable Assemblies

When it comes to selecting coaxial cable assemblies that meet the rigorous demands of data centers, FRS Factory delivers solutions engineered for performance, reliability, and longevity. With decades of experience in manufacturing high-frequency cable assemblies, FRS understands the unique challenges of data center environments—from EMI interference and high temperatures to the need for seamless scalability.

FRS coaxial cable assemblies are designed to excel in every critical category: they support frequencies up to 67 GHz, ensuring compatibility with 5G and next-gen networks; feature low attenuation to maintain signal integrity over long runs; and incorporate dual shielding to eliminate EMI in dense equipment setups. Our connectors, crafted from high-quality, corrosion-resistant materials, are precision-engineered for secure, low-loss connections, while our flexible yet durable jackets withstand the rigors of data center routing and temperature fluctuations.

Beyond off-the-shelf options, FRS offers fully customized assemblies—tailored lengths, connector combinations, and color-coding—to fit your exact infrastructure needs. Every FRS product undergoes rigorous testing to meet ISO 9001 and RoHS standards, guaranteeing consistent quality and compliance.

For data centers that demand uncompromising performance, FRS Factory is more than a supplier—we’re a partner in building resilient, future-ready networks. Trust FRS to deliver coaxial cable assemblies that keep your data center running at peak efficiency, today and tomorrow.

FAQ

NEWS

More Products

Our factory offers high-quality products at competitive prices

High-Speed Data Micro-Coax

High-Speed Data Micro-Coax

IntroductionIn today’s fast-paced digital world, reliable and high-speed data transmission is critical for industries ranging from telecommunications to aerospace. Enter ​High-Speed Data Micro-Coax—a cutting-edge miniature coaxial cable e.

Precision Instrument Micro-Coax

Precision Instrument Micro-Coax

H1: Precision Instrument Micro-Coax – Engineered for Critical Signal Integrity Meta Description: Discover Precision Instrument Micro-Coax: Miniature coaxial cable solution optimized for high-frequency signal transmissio.

Contact Us

Feel free to reach out to us for any inquiries or orders.

Call Us

Have a question? Give us a call!

+861881875005

Email Us

Send us an email and we'll get back to you soon.

sales@custom-cable-assemblies.com
       
Home Products Contact